CyberData 010935 Specifications Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
CyberData Corporation 930181E Operations Guide
Installing the VoIP Intercom
Intercom Setup
6
2.2 Intercom Setup
2.2.1 VoIP Intercom Connections
Figure 2-4 shows the pin connections on the J7 (terminal block). This terminal block can accept a
wire range from 16 AWG to 26 AWG.
Note As an alternative to using PoE power, you can supply 5 VDC at 1000 mA into the terminal
block.
Figure 2-4. VoIP Intercom Connections
1
2
3
4
Alternate Power Input:
1 = +5V at 1000 mA
2 = Power Ground
Relay Contact:
(2A at 30 VDC or 0.4A at 125 VAC
for continuous loads)
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Reference
J3 - Terminal Block
-
-
Wire in,
accept wire range
from 16-26 AWG
3
4
5
6
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 47 48

Comments to this Manuals

No comments