3. DefineemergencynotificationsinBellCommander:
a. ClicktheNotificationsbuttontoviewtheNotification s window.
b. ClickthetopAddorEditbuttontoaddoreditanotification.Fortheexample,we’lledit
thetornadonotification.
c. Intheeditwindow,notetheSIPcode.Thisisthecodethatthephoneusershoulddial
totriggertheemergencynotification.TheShowConfirmationoptionisforclicking
notificationsintheBellCommanderinterface.IfShowConfirmationischecked,a
messagewillpopuptorequestconfirmationofanemergencyalert.
d. Assignactionstotheemergencynotification.UsetheAddActionandEditActiontoadd
andeditactionsinthealertscripts.Typically,asoundfilewouldbeplayedandlooped.
Intheaction,thezoneshouldbesettoazonethatbroadcaststoallareasthatshould
receivethenotification.

4. Totriggeranemergencynotificationbyphone, firstcalltheBellCommanderextension,inthe
exampleabovethiswouldbe900.WaitforBellCommandertoanswer,thendialtheemergency
codefollowedbythe#key.Intheexampleabove991#.Tostopthealert,dial999#while
connectedtoBellCommander.ThealertcanalsobestoppedbydialingtheBellCommander
extensionagainandentering999#.